Tổng tiền thanh toán:
-
Sản phẩm đã được thêm vào giỏ hàng
Số lượng:
Tổng tiền:
CL-211-E CR PM2.5/CO/Temperature/Humidity/ Dew Point Data Logger Module (RS-485, Ethernet PoE) (RoHS)
CL-211-E CR: Cảm biến đo độ bụi PM2.5 + CO+ nhiệt độ + Độ ẩm Ethernet + RS-485 Modbus + MQTT
Features
Introduction
The CL-200 series of data logger devices can be used to record PM2.5, CO, CO2, temperature, humidity and dew point information, including the date and time stamps, and are able to store up to 450,000 downloadable records.
Real-time data can be accessed from the CL-200 data logger from anywhere and at any time using the free Windows software, the iOS App, or the Android App, as long as they are connected to the same local network as the data logger.
Support is provided for common industrial protocols such as DCON, Modbus RTU, and Modbus TCP, as well as the emerging machine-to-machine (M2M)/)IoT (Internet of Things) connectivity protocol – MQTT. The CL-200 data logger can be connected via widely used communication interfaces including RS-485, Ethernet and PoE, meaning that the device can be easily integrated into existing HMI or SCADA systems, ensuring trouble-free maintenance in distributed control systems.
Supports the MQTT Protocol for IoT Applications
Multi-platform Remote Access Software
Real-time data from the CL-200 data logger can be accessed from anywhere and at any time using the DL300 Utility, the iOS or Android App, or via a regular web browser, as long as they are connected to the same local network as the data logger.
Simple and Powerful CL-200-E Utility
The DL300 Utility can be used to configure the modules, monitor real-time data, group CL-200-E modules so that the status of distribution groups can be viewed and managed. The utility also allows the log data to be downloaded and exported to a .CSV file that can then be imported into any industry-standard software or spread sheet for analysis.
Specifications
Temperature Measurement | |
---|---|
Range | -10 ~ +50°C |
Resolution | 0.1°C |
Accuracy | ±0.6°C |
Humidity Measurement | |
---|---|
Accuracy | ±5% RH, Non-condensing |
Range | 0 ~ 100% RH, Non-condensing |
Resolution | 0.1% RH, Non-condensing |
Dew Point | |
---|---|
Range | Calculated using temperature and relative humidity |
Resolution | 0.1°C |
CO Measurement | |
---|---|
Range | 0 to 1000 ppm (Electrochemical) |
Resolution | 1 ppm |
Accuracy | ±5% of measured value |
Response Time | 30 seconds |
Warm-up Time | 5 minutes |
PM2.5 Measurement | |
---|---|
Range | 0 ~ 400 μg/m3 |
Resolution | 1μg/m3 |
Response Time | <= 1 min. |
System | |
---|---|
Alarm | PM2.5/RH/Temperature |
Real Time Clock | Yes |
Data Logger | Yes, up to 450,000 records |
Relay Output | |
---|---|
Channels | 1 x Form A, SPST 30 VDC @ 16 A or 250 VAC @ 16 A |
COM Ports | |
---|---|
Ports | 1 x RS-485 1 x Ethernet |
Protocol | DCON and Modbus/RTU (RS-485) Modbus TCP and MQTT (Ethernet) |
Ethernet | |
---|---|
Ports | 10/100 Base-TX, 8-Pin RJ-45 x1 (Auto-negotiating, Auto-MDI/MDIX, LED indicators) |
Power | |
---|---|
Consumption | Non-PoE: 2.66 W (Max.) PoE: 2.73 W (Max.) |
Powered from Terminal Block | +12 ~ +48 VDC |
Mechanical | |
---|---|
Dimensions (mm) | Ø 150 x 53 (Ø x H) |
Installation | Ceiling Mounting/Wall Mounting |
Ingress Protection Rating | IP20 |
Environmental | |
---|---|
Operating Temperature | 0 ~ 50°C |
Storage Temperature | -30 ~ +75°C |
Humidity | 10 ~ 90% RH, Non-condensing |
Download
Ordering infromation
CL-211-E CR | PM2.5/CO/Temperature/Humidity/ Dew Point Data Logger Module (RS-485, Ethernet PoE) (RoHS) |
Số lượng: