Feature

• Bi-directional Energy
• 8 Three Phase Circuits or 24 Single Phase Circuits
• True RMS Power Measurements
• Energy Analysis for 3P4W, 3P3W, 1P3W, 1P2W
• Measure different current ranges with different 333mV CTs
• Voltage Measurements Up to 500 V
• Easy install with split core CT
• W Accuracy Better than 5% (PF=1)
• Total Harmonic Distortion (THD)
• Support CANopen Protocol
• Support 2 Power Relay Output (Form A)

Introduction

The PM-4324P series multi-circuit power meter monitors up to 8 three-phase circuits or 24 single-phase circuits, or any combination of single or three-phase circuits. The PM-4324P series can measure up to 24 currents via external Current Transformers (CTs). This flexibility makes the PM-4324P series perfect for multi-tenant facilities such as residential projects, office buildings and shopping malls. This compact instrument is designed to easily fit into existing panelboards or be flush mounted nearby, thus eliminating the need for expensive retrofit projects or for allocating extra space for the device. You can use CT's that you currently own with PM-4324P (without CTs) Power Meter. The CT inputs of the PM-4324P can be directly input from the secondary side of 333mV CT.

Application

• Generator monitoring
• Switchgear distribution systems
• Energy Management
• Power quality analysis

Specifications

AC Power Measurement
Wiring 3P4W-3CT, 3P3W-2CT, 3P3W-3CT, 1P2W-1CT, 1P3W-2CT
Loops Multi-circuit
Input Voltage 10 ~ 500 V
Input Frequency 50/60 Hz
W Accuracy Better than 5% (PF=1)
Power Parameter Measurement True RMS voltage (Vrms), True RMS current (Irms), Active Power (kW), Active Energy (kWh), Apparent Power (kVA), Apparent Energy (kVAh),Reactive Power (kVAR), Reactive Energy (kVARh), Power Factor (PF), Frequency
Data Update Rate 1 Second
CT
Includes CTs 0
CANopen
Baud Rate 125 k (default), 250 k, 500 k, 1 M; DIP Switch Selectable
Isolation 3000 VDC
Protocol CANopen
Power
Input Range +85 ~ +264 VAC (277 VAC available)
Consumption 6 W
Alarm Output Form A (Normal Open) x 2; Relay Contact Voltage Range: 5 A @ 250 VAC (47 ~ 63 Hz), 5 A @ 30 VDC
Mechanical
Casing Metal
Dimensions (mm) 237 x 57 x 134 (W x L x H)
Installation DIN-Rail & wall mounting
Environment
Operating Temperature -20 ~ +70 °C
Storage Temperature -25 ~ +80 °C
Humidity 10 ~ 90% RH, Non-condensing

Download

Datasheet

Documents

Ordering Information

PM-4324P-CPS     CR  CANopen, Multi-Circuit Power Meter (Can be directly input from the secondary side of 333mV CT) (RoHS)