Bộ đổi nguồn Din-Rail 3 pha 340 ~ 550VAC AMLPULS AMTR96024N 960W, 24DC, 40A, PFC, DC/OK
Features
Three-Phase 340-550VAC wide range input
(Dual phase operation possible)
Width only 110mm
Built-in active PFC function compliance to BS EN/EN61000-3-2
High efficiency 94.5% and low power dissipation
Protections:Short circuit/Overload/Over voltage/Over temperature
Cooling by free air convection
Built-in constant current limiting circuit
Current sharing up to 3840W(3+1)
can be installed on DIN rail TS-35/7.5 or 15
Built DC OK relay contact
100% full load burn-in contact
1 years warranty
Specification
Input |
||
Voltage range Note.1 |
Three-Phase 340 ~ 550VAC (Dual phase operation possible) 480 ~ 780VDC |
|
Leakage current |
<3.5mA / 530VAC |
|
Frequency range |
47-63Hz |
|
Inrush current (Typ.) |
Cold start :60A |
|
Power factor(Typ.) |
PF≧0.88/400VAC PF≧0.86/500VAC at full load |
|
AC Current(Typ.) |
2A/400VAC 1.4A/500VAC |
|
Output |
||
DC voltage (V) |
24V |
48V |
Efficiency(TYP.) |
94% |
94.5% |
Rated Current (A) |
40A |
20A |
Current range(A) |
0-40A |
0-20A |
Rated power(W) |
960W |
960W |
Ripple & noise(max ) Note.2 |
180mVp-p |
250mVp-p |
Voltage ADJ.range |
24-28V |
48-55V |
Voltage tolerange Note.3 |
±1% |
±1% |
Line regulation |
±0.5% |
±0.5% |
Load regulation |
±1% |
±1% |
Setup,rise time |
1000ms 100ms/400VAC 800ms 100ms/500VAC(at full load) |
|
Hold up time(Typ.) |
12ms/400VAC 14ms/500VAC(at full load) |
|
Status indicator |
Green LED |
|
Protection |
||
Overload |
105 ~ 130% rated output power |
|
Protection type : Constant current limiting, unit will shut down after 3 sec. ,re-power on to recover |
||
Over voltage(V) |
29 ~ 33V |
56 ~ 65V |
Protection type : Shut down o/p voltage, re-power on to recover |
||
Over temperature |
Shut down o/p voltage, recovers automatically after temperature goes down |
|
DC OK Realy contact ratings(max.) |
60Vdc/0.3A, 30Vdc/1A, 30Vac/0.5A resistive load |
|
Current sharing |
Please refer to function manual |
|
Safety and EMC |
||
Withstand voltage |
I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC O/P-DC OK:0.5KVAC |
|
Isolation resistance |
I/P-O/P, I/P-FG, O/P-FG:>100M Ohms / 500VDC / 25℃/ 70% RH |
|
Safety standards |
Design reference UL508, AS/NZS62368.1, EAC TP TC 004 approved, IEC62368-1 CB approved by SIQ; Design refer to BS EN/EN62368-1 |
|
EMC emission |
Design reference BS EN/EN55032 (CISPR32), BS EN/EN61204-3 Class B, BS EN/EN61000-3-2,-3, EAC TP TC 020 |
|
EMC immunity |
Design reference BS EN/EN61000-4-2,3,4,5,6,8,11, BS EN/EN55024, BS EN/EN61000-6-2 (BS EN/EN50082-2), BS EN/EN61204-3, heavy industry level, EAC TP TC 020 |
|
Environmental |
||
Working temperature Note.5 |
- 30~+70 ℃ (Refer to "Derating curve ") |
|
Storage TEMP.humidity |
-40~+85℃ 10 ~ 95% RH non-condensing |
|
Working humidity |
20 ~ 95% RH non-condensing |
|
TEMP.coefficient |
±0.03%/℃ (0 ~ 50℃) |
|
Vibration |
Component:10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes; Mounting: Compliance to IEC60068-2-6 |
|
Others |
||
Mean time between failure |
647.1K hrs min MIL-HDBK-217F(25℃) |
|
Installation |
Install on DIN rail TS35 |
|
Weight |
About 2.47kg |
|
Length*width*height |
110*125.2*150mm |
|
Data |
Details |
Model name |
|
AMTR 960W 40A/24V |
AMTR96024N |
AMTR 960W 20A/48V |
AMTR96048N |
Download