Module RS-485 Modbus RTU 2 kênh đầu vào bộ đếm/tần số (Counter/Frequency) ICP DAS M-7080D-G CR
Features
• 2-channel Counter/Frequency Input
• 32-bit Counter
• Isolated or Non-isolated Input
• Programmable Alarm Output
• Programmable Digital Filter
• Programmable Threshold Voltage Level
• Maximum Frequency of up to 100 kHz
• Built-in Virtual Battery Backup to Preserve Counter Values (I-7080B(D), M-7080B(D))
• Dual Watchdog
• Wide Operating Temperature Range: -25 ~ +75°C
Introduction
The I-7080 offers 2 high speed counter or frequency input channels and 2 digital output channels. Two types of digital input are provided, one for isolated input, and the other is for non-isolated input. The isolated input provides 3750 Vrms isolation voltage and the non-isolated input provides programmable threshold voltage level. The built-in digital filter is valid for both non-isolated and isolated input and can filter out noise where the high/low pulse width is smaller than the minimum high/low width of the digital filter. The maximum count is up to 32-bit and the maximum frequency is up to 100 kHz. The module also provides programmable alarm output with non-isolated open collectors. The M-7080 supports both the Modbus RTU and DCON protocols, which can be configured via software, and all hardware specifications are the same as the I-7080. The functions of the I-7080B are the same as that of the I-7080, except that the I-7080B provides a virtual battery backup function in counter mode
Specification
CPU Module | |
---|---|
Watchdog Timer | Yes, Module (1.6 Seconds), Communication (Programmable) |
Display | |
---|---|
Type | 5-Digit 7 Segment LED Display |
Isolation | |
---|---|
Intra-module Isolation | 3000 VDC |
EMS Protection | |
---|---|
EFT (IEC 61000-4-4) | ±4 kV for Power Line |
ESD (IEC 61000-4-2) | ±4 kV Contact for each Terminal |
Surge (IEC 61000-4-5) | ±0.5 kV for Power Line |
LED Indicators | |
---|---|
Status | 1 x Power and Communication |
Digital Input | |
---|---|
Programmable Threshold Voltage | +0.1 ~ +5 VDC |
Digital Output | |
---|---|
Channels | 2 |
Type | Open Collector |
Sink/Source (NPN/PNP) | Sink |
Load Voltage | +3.5 ~ +30 VDC |
Max. Load Current | 30 mA/Channel |
Counter/Frequency/Encoder Input | |
---|---|
Channels | 2 |
Type | Counter, Frequency |
Sink/Source (NPN/PNP) | Sink |
Counter/Encoder Bits | 32-bit |
ON Voltage Level | Isolated: +3.5 ~ +30 VDC Non-isolated: +2.4 ~ +5 VDC |
OFF Voltage Level | +1 VDC Max. |
Frequency Accuracy | 1 Hz or 10 Hz |
Individual Channel Configuration | No |
Counter Mode | Up |
Frequency Mode | Yes |
Max. Speed | 100 KHz |
Low Pass Filter | 2 μs to 65 ms |
COM Ports | |
---|---|
Ports | 1 x RS-485 |
Baud Rate | 1200 ~ 115200 bps |
Data Format | (N, 8, 1) (N, 8, 2) (E, 8, 1) (O, 8, 1) |
Protocol | Modbus RTU, DCON |
Power | |
---|---|
Reverse Polarity Protection | Yes |
Input Range | +10 ~ +30 VDC |
Consumption | 2.2 W |
Mechanical | |
---|---|
Dimensions (mm) | 123 x 72 x 35 (W x L x H) |
Installation | DIN-Rail |
Environmental | |
---|---|
Operating Temperature | -25 ~ +75 °C |
Storage Temperature | -40 ~ +85 °C |
Humidity | 10 ~ 95% RH, Non-condensing |
Download
Ordering information
M-7080D-G CR | 2-ch Counter/Frequency Input Module with LED Display using DCON and Modbus Protocols (Gray Cover) (RoHS) |