Module RS-485 DCON 1 kênh đầu vào tương tự cặp nhiệt Thermocouple + 2 kênh DO+1 kênh DI ICP DAS I-7011PD CR
Features
• 1-channel Analog Input
• Current, Voltage or Thermocouple Input
• Open Thermocouple Detection
• High Resolution: 16-bit
• 1-channel Digital Input as 50 Hz Event Counter
• 1-channel Digital Output as High/Low Alarm
• 3000 VDC Intra-module Isolation
• Dual Watchdog
• Wide Operating Temperature Range: -25 to +75°C
Introduction
The I-7011 series of modules feature current and voltage input, as well as thermocouple input. The module provides 1-channel Analog Input, 1-channel Digital Input that functions as a 50 Hz event counter, and 2-channel Digital Output that can be used as a high/low alarm. The module also features open wire detection for the thermocouple input, and 3000 VDC intra-module isolation. The M-7011 supports both the Modbus RTU and DCON protocols, which can be configured via software, and all hardware specifications are the same as the I-7011. The I-7011P provides support for two additional thermocouple types, L and M.
Application
• Building Automation
• Factory Automation
• Machine Automation
• Remote Maintenance
• Remote Diagnosis
• Testing Equipment
Specification
| CPU Module | |
|---|---|
| Watchdog Timer | Yes, Module (1.6 Seconds), Communication (Programmable) |
| Display | |
|---|---|
| Type | 5-Digit 7 Segment LED Display |
| Isolation | |
|---|---|
| Intra-module Isolation | 3000 VDC |
| EMS Protection | |
|---|---|
| EFT (IEC 61000-4-4) | ±4 kV to Power Line |
| ESD (IEC 61000-4-2) | ±2 kV Contact for each Terminal |
| Surge (IEC 61000-4-5) | ±0.5 kV for Power Line |
| LED Indicators | |
|---|---|
| Status | 1 x Power and Communication |
| Analog Input | |
|---|---|
| Channels | 1 Differential |
| Type | Voltage Current Thermocouple |
| Sensor Type | Thermocouple: J, K, T, E, R, S, B, N, C, L, M |
| Range | Voltage: ±15 mV, ±50 mV, ±100 mV, ±500 mV, ±1 V, ±2.5 V Current: ±20 mA (requires optional external 125 Ω resistor) |
| Resolution | 16-bit |
| Accuracy | ±0.1% of FSR |
| Sampling Rate | 10 Hz (Total) |
| Input Impedance | > 400 kΩ |
| Common Voltage Protection | ±5 VDC |
| Overvoltage Protection | ±5 VDC |
| Open Wire Detection | Yes |
| Digital Input/Counter | |
|---|---|
| Channels | 1 |
| Type | Dry Contact |
| Sink/Source (NPN/PNP) | Source |
| Dry Contact, ON Voltage Level | Close to GND |
| Dry Contact, OFF Voltage Level | Open |
| Input Impedance | 3 kΩ |
| Overvoltage Protection | ±30 VDC |
| Digital Output | |
|---|---|
| Channels | 2 |
| Type | Open Collector |
| Sink/Source (NPN/PNP) | Sink |
| Load Voltage | +3.5 ~ +30 VDC |
| Max. Load Current | 30 mA/Channel |
| Power on Value | Yes |
| Safe Value | Yes |
| COM Ports | |
|---|---|
| Ports | 1 x RS-485 |
| Baud Rate | 1200 to 115200 bps |
| Data Format | N, 8, 1 |
| Protocol | DCON |
| Power | |
|---|---|
| Reverse Polarity Protection | Yes |
| Input Range | +10 ~ +30 VDC |
| Consumption | 1.5 W |
| Mechanical | |
|---|---|
| Dimensions (mm) | 123 x 72 x 35 (W x L x H) |
| Installation | DIN-Rail |
| Environmental | |
|---|---|
| Operating Temperature | -25 ~ +75 °C |
| Storage Temperature | -40 ~ +85 °C |
| Humidity | 10 ~ 95% RH, Non-condensing |
Download
Odering information
| I-7011PD CR | 1-ch Thermocouple Input Module with LED Display using DCON Protocol (Blue Cover) (RoHS) |