Bộ chuyển đổi Gateway Modbus/OPC UA sang EtherCAT ICP DAS ECAT-2600i CR
Features
Introduction
The ECAT-2600i is a proven and trusted protocol converter gateway module that allows you to seamlessly inter-connect devices between EtherCAT and Modbus/OPC UA networks. The ECAT-2600i acts as a MainDevice on EtherCAT networks, allowing I/O data to be transferred between the two networks. The ECAT-2600i provides a data exchange buffer that allows two different systems (EtherCAT and the Modbus/OPC UA) exchange data easily and faster for more diverse applications.

ECAT-2600i provides an easy-to-use and intuitive web interface that allows users to implement IF-THEN-ELSE control logic with just a few clicks; no programming is required. The built-in IF-THEN-ELSE logic engine executes the automation logic in a stable and efficient manner. It also provides functions for mathematical operations, scheduling, and sending alarms via e-mail.
An OPC UA server is part of the ECAT-2600i firmware and is a secure, open and reliable mechanism for information transfer. OPC UA is used for horizontal communication between machines and vertical communication between the machine and a higher level IT system (SCADA, Cloud). All standard OPC UA clients can connect directly to the ECAT-2600i without customization, reducing the cost of integration or application software development.
Applications
Specifications
| Software | |
|---|---|
| Function | • Web Interface for Configuration • IF-THEN-ELSE Logic operation • I/O channel monitoring and control • Timer operation • Schedule operation • Internal Register operation • Email sending function |
| Ethernet | |
|---|---|
| Ports | RJ-45 x 1 Distance between Stations: Max. 100 m (100BASE-TX) PoE (IEEE 802.3af, Class 2) |
| Protocol | Modbus TCP, Modbus TCP/TLS, Modbus UDP, OPC UA, MQTT, Rest API, CoAP, LwM2M, SNMP, SMTP, SNTP, HTTP/HTTPS |
| COM Ports | |
|---|---|
| Ports | 1 x 422/485 |
| Protocol | Modbus RTU (Salve) |
| EtherCAT | |
|---|---|
| Ports | RJ-45 x 1 Distance between Stations: Max. 100 m (100BASE-TX) Data Transfer Medium: Ethernet/EtherCAT Cable (Min. CAT 5e) |
| Cycle Time | 0.125 ~ 32ms |
| Distributed Clocks | Yes |
| Power | |
|---|---|
| Consumption | 0.22 A @ 24 VDC |
| Powered from PoE | IEEE 802.3af, Class 2 |
| Powered from Terminal Block | +12 ~ 48 VDC |
| Mechanical | |
|---|---|
| Casing | Plastic |
| Dimensions (mm) | 33 x 127 x 99 (W x L x H) |
| Installation | DIN-Rail |
| Environment | |
|---|---|
| Operating Temperature | -25 ~ +75 °C |
| Storage Temperature | -30 ~ +80 °C |
| Humidity | 10 ~ 90% RH, Non-condensing |
Download
Ordering Information
| ECAT-2600i CR | Modbus/OPC UA to EtherCAT Main Device Accelerator (RoHS) |