Bộ đổi nguồn tổ ong MCTT-LRS-100-36 100W, 36VDC, 2.8A
MCTT-LRS-100 series is a 100W single output enclosed type power supply with 30mm of low profile design. Adopting the full range 85~264VAC input, the entire series provides an output voltage line of 5V, 12V, 24V, 36V and 48V.
In addition to the high efficiency up to 91%, the design of metallic mesh case enhances the heat dissipation of MCTT-LRS-100 that the whole series operates from -30 ~ 70℃ under air convection without a fan. Delivering an extremely low no load power consumption (less than 0.3W), it allows the end system to easily meet the worldwide energy requirement. MCTT-LRS-100 has the complete protection functions and 5G anti-vibration capability; it is complied with the international safety regulations such as UL60950-1, IEC/EN60950-1, IEC/EN61558-2-16, IEC/EN60335-1 and CCC GB4943. MCTT-LRS-100 series serves as a high price-to-performance power supply solution for various industrial applications.
Features:
Specifications
SPECIFICATION |
|
||||||||||||
OUTPUT |
|
||||||||||||
Model |
MCTT-LRS-100-3.3 |
MCTT-LRS-100-5 |
MCTT-LRS-100-12 |
MCTT-LRS-100-15 |
MCTT-LRS-100-24 |
MCTT-LRS-100-36 |
MCTT-LRS-100-48 |
||||||
DC Voltage |
3.3V |
5V |
12V |
15V |
24V |
36V |
48V |
||||||
Rated Current |
20A |
18A |
8.5A |
7A |
4.5A |
2.8A |
2.3A |
||||||
Current Range |
0~20A |
0~18A |
0~8.5A |
0~7A |
0~4.5A |
0~2.8A |
0~2.3A |
||||||
Rated Power |
66W |
90W |
102W |
105W |
108W |
100.8W |
110.4W |
||||||
Ripple&Noise |
100mVp-p |
100mVp-p |
120mVp-p |
120mVp-p |
150mVp-p |
200mVp-p |
200mVp-p |
||||||
VoltageAdj. Range |
2.97~3.6V |
4.5 ~ 5.5V |
10.2~ 13.8V |
13.5~18V |
21.6~28.8V |
32.4~39.6V |
43.2~52.8V |
||||||
Voltage Tolerance |
±3.0% |
±2.0% |
±1.0% |
±1.0% |
±1.0% |
±1.0% |
±1.0% |
||||||
Line Regulation |
±0.5% |
±0.5% |
±0.5% |
±0.5% |
±0.5% |
±0.5% |
±0.5% |
||||||
Load Regulation |
±2.0% |
±1.0% |
±0.5% |
±0.5% |
±0.5% |
±0.5% |
±0.5% |
||||||
Setup,Rise Time |
500ms, 30ms/230VAC 500ms, 30ms/115VAC at full load |
||||||||||||
Hold Up Time |
55ms/230VAC 10ms/115VAC at full load |
||||||||||||
|
|
||||||||||||
INPUT |
|
||||||||||||
Voltage Range |
85 ~ 264VAC 120 ~ 373VDC |
||||||||||||
Frequency Range |
47 ~ 63Hz |
||||||||||||
Efficiency |
84.5% |
86% |
88% |
88.5% |
90% |
90.5% |
91% |
||||||
AC Current |
1.9A/115VAC 1.2A/230VAC |
||||||||||||
Inrush Current |
Cold start 50A/230VAC |
||||||||||||
Leakage Current |
<0.75mA / 240VAC |
||||||||||||
|
|
||||||||||||
PROTECTION |
|
||||||||||||
Over Load |
110 ~ 150% rated output power |
||||||||||||
Protection type: Hiccup mode, recovers automatically after fault condition is removed |
|||||||||||||
Over Voltage |
3.8~4.45V |
5.75~6.75V |
13.8~16.2V |
18.75~21.75V |
28.8~33.6V |
41.4~48.6V |
55.2~64.8V |
||||||
Protection type: shut down o/p voltage, re-power on to recover |
|||||||||||||
|
|
||||||||||||
ENVIRONMENT |
|
||||||||||||
Working Temp. |
-30 ~ +70℃ (Refer to “derating curve”) |
||||||||||||
Working Humidity |
20 ~ 90% RH non-condensing |
||||||||||||
StorageTemp., Humidity |
-40 ~ +85℃, 10 ~ 95% RH |
||||||||||||
Temp. Coefficient |
±0.03%/℃ (0 ~ 50℃) |
||||||||||||
Vibration |
10 ~ 500Hz, 5G 10min./1cycle, 60min. each along X, Y, Z axes |
||||||||||||
|
|
||||||||||||
SAFETY &EMC |
|
||||||||||||
Safety Standards |
UL60950-1, TUV EN60950-1, EN60335-1/-2-16, CCC GB4943 approved |
||||||||||||
Withstand Voltage |
I/P-O/P:3.75KVAC I/P-FG:2KVAC O/P-FG:1.25KVAC |
||||||||||||
Isolation Resistance |
I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25℃ / 70% RH |
||||||||||||
EMC Emission |
Compliance to EN55022(CISPR22), GB9254 CLASS B, EN55014 EN 61000-3-2,-3 |
||||||||||||
EMC Immunity |
Compliance to EN61000-4-2,3,4,5,6,8,11, EN61000-6-2(EN50082-2), heavy industry level, criteria A |
||||||||||||
|
|
||||||||||||
OTHERS |
|
||||||||||||
Dimension |
129*97*30mm (L*W*H) |
||||||||||||
Weight |
0.34Kg |
||||||||||||
Packing |
40pcs/carton/14.6kg/0.92CUFT |
||||||||||||
|
|
||||||||||||
NOTE |
|
||||||||||||
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25℃ of ambient temperature. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12” twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 3. Tolerance: includes set up tolerance, line regulation and load regulation. 4. Line regulation is measured from low line to high line at rated load. 5. Load regulation is measured from 0% to 100% rated load. 6. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meetsEMC directives. 7. Length of set up time is measured at cold first start. Turning ON/OFF the power supply very quickly may lead to increase of the set up time. |
Download