Thiết bị đo điện thông minh 1 pha 1P4W-4CT 200A CANopen ICP DAS PM-3114-240-CPS CR
Features
• True RMS Power Measurements
• Energy Analysis for 1P2W, 1P4W
• Current Measurements Up to 200 A with Different CT Ratio
• Voltage Measurements Up to 300 V
• Clip-on CT for Easy Installation
• W Accuracy Better than 0.5% (PF=1)
• Supports CANopen Protocol
• Supports 2 Power Relay Output (Form A)
• IEC 61010-1 and EN 61010-1
Introduction
ICP DAS brings the most powerful, cost-effective, advanced Smart Power Meters PM-3000 series that gives you access to real-time electric usage for single-phase power measurement. With its high accuracy (< 0.5%, PF=1 ), the PM-3000 series can be applied to both low voltage primary side and/or medium/high voltage secondary side and enables the users to obtain reliable and accurate energy consumption readings from the monitored equipments in real time under operation. These compact size and cost-effective power meters are equipped with revolutionary wired clip-on CT (various types, support input current up to 200 A). It operates over a wide input voltages range 10 ~ 300 VAC which allows worldwide compatibility. And with 2 channels relay outputs, it can be linked with sirens or lightings for alarm messages. It also supports Modbus RTU, Modbus TCP or CANopen protocols for easy integration.
Application
• Generator monitoring
• Switchgear distribution systems
• Energy Management
• Power quality analysis
Specification
AC Power Measurement | |
---|---|
Wiring | 1P4W-4CT |
Loops | Single-phase |
Input Voltage | 10 ~ 300 V |
Input Current | CTØ24 mm (0.15 A ~ 200 A) |
Input Frequency | 50/60 Hz |
W Accuracy | Better than 0.5% (PF=1) |
Power Parameter Measurement | True RMS voltage (Vrms), True RMS current (Irms), Active Power (kW), Active Energy (kWh), Apparent Power (kVA), Apparent Energy (kVAh), Reactive Power (kVAR), Reactive Energy (kVARh), Power Factor (PF), Frequency |
Data Update Rate | 1 Second |
CT | |
---|---|
Includes CTs | 4 |
Type | Clip |
Max. Current | 200 A |
Inside Diameter | 24 mm |
Leading Cable | 1.8 m |
CANopen | |
---|---|
Baud Rate | 125 k (default), 250 k, 500 k, 1 M; DIP Switch Selectable |
Porotocol | CANopen |
Power | |
---|---|
Input Range | +12 ~ 48 VDC |
Consumption | 2W |
Alarm Contact | Form A (Normal Open) x 2; Relay Contact Voltage Range: 5 A @ 250 VAC (47 ~ 63Hz), 5 A @ 30 VD |
Mechanical | |
---|---|
Casing | Plastic |
Dimensions (mm) | 33 x 127 x 100 (W x L x H) |
Installation | DIN-Rail Mounting |
Environmental | |
---|---|
Operating Temperature | -20 ~ +70 °C |
Storage Temperature | -25 ~ +80 °C |
Humidity | 10 ~ 90% RH, Non-condensing |
Download
Ordering information
PM-3114-240-CPS CR | CANopen, 4 loops single-phase Power Meter; includes 200A CT (Inside diameter 24 mm; wire lead 1.8 m) x 4 (RoHS) |