-
-
-
Tổng tiền thanh toán:
-
Sản phẩm đã được thêm vào giỏ hàng
Số lượng:
Tổng tiền:
8-channel Universal Input with High Voltage Protection and 4-channel Isolated Output PoE Module
Module lập trình nhúng Wise IoT 8 kênh AI + 6 kênh DO ICP DAS WISE-7119 CR
WISE (Web Inside, Smart Engine) is a product series developed by ICP DAS that functions as control units for use in remote logic control and monitoring in various industrial applications. WISE offers a user-friendly and intuitive web site interface that allows users to implement IF-THEN-ELSE control logic on controllers just a few clicks away; no programming is required. With its powerful and easy-to-use features, it will minimize the learning curve, shorten time to market and dramatically reduce the effort and cost spent on system development.
WISE-7119 follows IEEE 802.3af-compliant (classification, Class 1) Power over Ethernet (PoE) specification. It allows receiving power from PoE enabled network by Ethernet pairs (Category 5 Ethernet cable). This feature provides greater flexibility and higher efficiency therefore simplifying systems design, saving space, reducing cables and eliminating the requirement for dedicated electrical outlets. Meanwhile, in case under a non-PoE environment, WISE-7119 will still be able to receive power from auxiliary power sources like AC adapters or battery, etc.
This multi-function module WISE-7119 supports Modbus/TCP protocol to make seamless integration with SCADA software available. It features 16-bit, 8-channel differential analog inputs and 4-channel digital ouputs. Each analog channel is allowed to configure an individual range and has 240 Vrms high over voltage protection.
Analog Input | ||
Input Channels | 8 (Differential) | |
Input Type(jumper selectable) | ±15 mV, ±50 mV, ±100 mV, ±50 mV, ±500 mV, ±1 V, ±5 V, ±10 V | |
Thermocouple (J, K, T, E, R, S, B, N, C, L, M,LDIN43710) | ||
±20mA, 0~20mA, 4~20mA | ||
Resolution | 16-bit | |
Sampling Rate | 10 samples/Sec. total | |
Accuracy | ±0.1% or better | |
Zero Drift | ±10 μV/°C | |
Span Drift | ±25 ppm/°C | |
Input Impedance | Voltage | >1 MΩ |
Current | 125 Ω | |
Common Mode Rejection | 86 dB Min. | |
Normal Mode Rejection | 100 dB | |
Over Voltage Protection | 240 Vrms | |
Individual Channel Configuration | Yes | |
Open Wire Detection | Yes | |
Digital Output | ||
Output Channels | 4 | |
Output Type | Isolated Open Collector (Sink) | |
Max. Load Current | 700 mA/Channel | |
Load Voltage | 5 VDC ~ 50 VDC | |
Overvoltage Protection | 60 VDC | |
Overload Protection | 1.4 A | |
Short-circuit Protection | Yes | |
System | ||
CPU | 16-bit CPU | |
SRAM | 512 KB | |
Flash Memory | 512 KB | |
EEPROM | 16 KB | |
Watchdog | Yes | |
Communication | ||
PoE Ethernet Port | 10/100 Base-TX and automatic MDI/MDI-X | |
2 Way Isolation | ||
I/O | 2500 VDC | |
EMS Protection | ||
ESD (IEC 61000-4-2) | ±4 kV Contact for each terminal and ±8 kV Air for random point | |
EFT (IEC 61000-4-4) | ±4 kV for Power Line | |
LED Indicators | ||
PoE | PoE On | |
L1 | System Running | |
L2 | Ethernet Link/Act | |
L3 | Ethernet 10/100M Speed | |
Power Requirements | ||
Reserve Polarity Protection | Yes | |
Powered from terminal block | Yes, 12 ~ 48 VDC | |
Powered from PoE | Yes, IEEE 802.3af, Class1 | |
Consumption | 3.4 W | |
Mechanical | ||
Dimensions(W x L x H ) | 123 mm x 72 mm x 35 mm | |
Installation | DIN-Rail or Wall mounting | |
Environment | ||
Operating Temperature | -25°C ~ +75 °C | |
Storage Temperature | -30°C ~ +80 °C | |
Relative Humidity | 10 ~ 90% RH, non-condensing |
Functions | |
Rule Configuration Website | Access Web server on WISE controllers to edit and upload logic rules through web browser. |
36 IF-THEN-ELSE Logic Rules | 3 IF conditions with AND or OR operators 3 THEN actions and 3 ELSE actions |
48 Internal Registers | Hold temporary variables and read/write data via Modbus/TCP address. |
12 Timers | Delay / Timing functions. |
12 Emails | Send Email messages to pre-set Email receivers. |
12 CGI Commands | Send pre-set CGI commands. |
12 Recipes | Set up THEN/ELSE action groups. |
8 P2P remote modules | Set up the connection information for the remote WISE modules. |
Modbus/TCP Protocol | Real time control and monitoring I/O channels and system status of controllers via SCADA software. |
IF Conditions | |
AI Channel | = 、> 、< 、 ≥ 、 ≤ (value) |
Internal Register | |
DO Counter | = 、> 、< 、 ≥ 、 ≤ (value)、Change |
Timer | Timeout、Not Timeout |
P2P | DI、AI、DI counter、DO counter、IR |
Rule Status | Enable、Disable |
THEN / ELSE Actions | |
DO Channel | ON、OFF、Pulse Output |
Internal Register | Change the value |
DO Counter | Reset |
Timer | Start、Stop |
Send | |
CGI Commands | |
Recipe | Execute |
P2P | DO(On/Off)、AO、IR |
Rule Status | Enable、Disable |
Download
Odering information
8-channel Universal Input with High Voltage Protection and 4-channel Isolated Output PoE Module (RoHS)
Số lượng:
Tổng tiền: