Tổng tiền thanh toán:
-
Sản phẩm đã được thêm vào giỏ hàng
Số lượng:
Tổng tiền:
CAN to Single-mode Fiber Bridge
Bộ chuyển đổi CAN sang Quang (Dual Fiber, Single Mode, SC, 30KM) ICP DAS I-2533CS CR
Feature
Introduction
The I-2533CS is a local CAN bridge used to establish a connection between two CAN bus system via single mode fiber optic transmission medium. In order to solve the problem between CAN and fiber transmission medium, the I-2533CS is specially designed for converting the electrical CAN bus signal to fiber optic cables. I-2533CS has three more important features. First, the transmission distance limitation of the CAN bus system will not affected due to the different CAN baud rate. It means that the total CAN bus working distance can be extended. Second, the bus error on one CAN network will not affect the operation of another CAN network. Finally, the two CAN network can communication with each other by using different CAN baud rate for highly flexibility.
The I-2533CS series is designed for single mode fiber, and allow to extern CAN bus to maximum 30 km. Besides, I-2533CS provides the group function, which is the basic message router. Users can decide the CAN message flows between several CAN bus systems. I-2533CS series also provides the utility tool for user-defined baud rate and filter configuration. By using this tool, it is allowed to have user-defined baud rate and CAN message filter. When users use the I-2533CS series on two CAN network with different CAN baud rate, it may be useful to reduce the bus loading of the network which has low baud rate.
Application
Specifications
LED Indicators | |
---|---|
Status | 1 x Power 3 x CAN status 2 x Fiber status |
COM Ports | |
---|---|
Ports | 1 x RS-232 (Utility Port) |
Fiber | |
---|---|
Ports | Single-Mode; SC Duplex connector x 1; 100 Base-FX |
Fiber Cable | 8.3/125, 8.7/125, 9/125 or 10/125 μm |
Wavelength | 1310 nm |
TX Output | -15 dBmMin. , -8 dBm Max. |
RX Sensitivity | -34 dBm Max. |
RX Overload | -5 dBm Max. |
Budget | 19 dBm |
Propagation Delay | 190 us (*Note1) |
Distance Between Stations | 30 km (9/125 μm recommended) |
CAN | |
---|---|
Ports | 1 |
Baud Rate | 10 k ~ 1 M bps |
Isolation | 500 Vrms on the CAN side |
Terminal Resistor | Switch for 120Ω terminal resistor |
Specification | ISO 11898-2, CAN 2.0A and CAN 2.0B |
Filter | Yes |
Power | |
---|---|
Input Range | +10 VDC ~ +30 VDC |
Consumption | 3 W |
Mechanical | |
---|---|
Casing | Plastic |
Dimensions (mm) | 33 x 126 x 101 (W x L x H) |
Installation | DIN-Rail |
Environment | |
---|---|
Operating Temperature | -25 ~ +75 °C |
Storage Temperature | -30 ~ +80 °C |
Humidity | 10 ~ 90% RH, Non-condensing |
Specification Memo
Note1: The propagation delay depends on the CAN Bus baud rate and the CAN message format. This value has been tested using a CAN baud rate of 1 Mbps, the CAN ID 0x12345678 and 8 bytes of data with a value of 0xFF.
Download
Ordering Information
I-2533CS CR | CAN to Single-mode Fiber Bridge; 1 (30 km) single-mode, SC connector (RoHS) |