Features
2-channel Counter/Frequency Input
32-bit Counter
Isolated or Non-isolated Input
Programmable Alarm Output
Programmable Digital Filter
Programmable Threshold Voltage Level
Maximum Frequency of up to 100 kHz
Built-in Virtual Battery Backup to Preserve Counter Values
(I-7080B(D), M-7080B(D))
Dual Watchdog
Wide Operating Temperature Range: -25 ~ +75°C
Introduction
The I-7080 offers 2 high speed counter or frequency input channels and 2 digital output channels. Two types of digital input are provided, one for isolated input, and the other is for non-isolated input. The isolated input provides 3750 Vrms isolation voltage and the non-isolated input provides programmable threshold voltage level. The built-in digital filter is valid for both non-isolated and isolated input and can filter out noise where the high/low pulse width is smaller than the minimum high/low width of the digital filter. The maximum count is up to 32-bit and the maximum frequency is up to 100 kHz. The module also provides programmable alarm output with non-isolated open collectors. The M-7080 supports both the Modbus RTU and DCON protocols, which can be configured via software, and all hardware specifications are the same as the I-7080. The functions of the I-7080B are the same as that of the I-7080, except that the I-7080B provides a virtual battery backup function in counter mode.
Application
Building Automation
Factory Automation
Machine Automation
Remote Maintenance
Remote Diagnosis
Testing Equipment
I/O Specification
|
Models |
I-7080/I-7080D |
I-7080B/I-7080BD |
M-7080/M-7080D |
M-7080B/M-7080BD |
|
|
Frequency/Counter Input |
|||||
|
Channels |
2 |
||||
|
Contact |
Wet |
||||
|
Sink/Source (NPN/PNP) |
Sink |
||||
|
On Voltage Level |
Isolated |
+3.5 ~ +30 VDC |
|||
|
Non-isolated |
+2.4 ~ +5 VDC |
||||
|
Off Voltage Level |
+1 VDC Max. |
||||
|
Programmable Filter |
2 μs to 65 ms |
||||
|
Programmable Threshold Voltage |
+0.1 ~ +5 VDC |
||||
|
Individual Channel Configuration |
No |
||||
|
Counter/Encoder-bits |
32-bit |
||||
|
Counter Mode |
Up |
||||
|
Encoder Mode |
- |
||||
|
Frequency Mode |
Yes |
||||
|
Virtual Battery Backup |
- |
Yes |
- |
Yes |
|
|
Frequency Accuracy |
1 Hz or 10 Hz |
||||
|
Max. Speed |
100 KHz |
||||
|
Digital Output |
|||||
|
Channels |
2 |
||||
|
Type |
Open Collector |
||||
|
Sink/Source (NPN/PNP) |
Sink |
||||
|
Load Voltage |
+3.5 ~ +30 VDC |
||||
|
Max. Load Current |
30 mA/Channel |
||||
System Specification
|
Models |
I-7080 |
I-7080D |
I-7080B |
I-7080BD |
M-7080 |
M-7080D |
M-7080B |
M-7080BD |
|
Communication |
||||||||
|
Interface |
RS-485 |
|||||||
|
Format |
(N, 8, 1) (N, 8, 2) (E, 8, 1) (O, 8, 1) |
|||||||
|
Baud Rate |
1200 ~ 115200 bps |
|||||||
|
Protocol |
DCON |
Modbus RTU, DCON |
||||||
|
Dual Watchdog |
Yes, Module (1.6 Seconds), Communication (Programmable) |
|||||||
|
LED Indicator/Display |
||||||||
|
System LED Indicator |
Yes, 1 LED as Power/Communication Indicator |
|||||||
|
I/O LED Indicator |
- |
|||||||
|
7-Segment LED Display |
- |
Yes |
- |
Yes |
- |
Yes |
- |
Yes |
|
Isolation |
||||||||
|
Intra-Module Isolation, Field-to-Logic |
3000 VDC |
|||||||
|
EMS Protection |
||||||||
|
ESD (IEC 61000-4-2) |
±4 kV Contact for each Terminal |
|||||||
|
EFT (IEC 61000-4-4) |
±4 kV for Power Line |
|||||||
|
Surge (IEC 61000-4-5) |
±0.5 kV for Power Line |
|||||||
|
Power |
||||||||
|
Reverse Polarity Protection |
Yes |
|||||||
|
Input Range |
10 ~ 30 VDC |
24 ~ 30 VDC |
10 ~ 30 VDC |
24 ~ 30 VDC |
||||
|
Consumption |
2.0 W |
2.2 W |
2.0 W |
2.2 W |
2.0 W |
2.2 W |
2.0 W |
2.2 W |
|
Mechanical |
||||||||
|
Dimensions (W x L x H) |
72 mm x 123 mm x 35 mm |
|||||||
|
Installation |
DIN-Rail or Wall Mounting |
|||||||
|
Environment |
||||||||
|
Operating Temperature |
-25 ~ +75°C |
|||||||
|
Storage Temperature |
-40 ~ +85°C |
|||||||
|
Humidity |
10 ~ 95% RH, Non-condensing |
|||||||
Download
Odering information
|
I-7080 CR |
2-channel Counter/Frequency Input Module with DCON Protocol (Blue Cover) (RoHS) |
|
I-7080-G CR |
2-channel Counter/Frequency Input Module with DCON Protocol (Gray Cover) (RoHS) |
|
I-7080D CR |
I-7080 with 7-segment LED Display (Blue Cover) (RoHS) |
|
I-7080B-G CR |
2-channel Counter/Frequency Input Module with DCON Protocol with Virtual Battery Backup (Gray Cover) (RoHS) |
|
I-7080BD-G CR |
I-7080B with 7-segment LED Display (Gray Cover) (RoHS) |
|
M-7080-G CR |
2-channel Counter/Frequency Input Module with DCON and Modbus Protocol (Gray Cover) (RoHS) |
|
M-7080D-G CR |
M-7080 with 7-segment LED Display (Gray Cover) (RoHS) |
|
M-7080B-G CR |
2-channel Counter/Frequency Input Module with DCON and Modbus Protocol with Virtual Battery Backup (Gray Cover) (RoHS) |
|
M-7080BD-G-G CR |
M-7080B with 7-segment LED Display (Gray Cover) (RoHS) |