Module RS-485 DCON 1 kênh đầu vào tương tự (Strain Gauge, 6 Wires) + 4 kênh DO + 1 kênh DI ICP DAS I-7016P CR
Features
• Long-distance Strain Gauge Measurement
• High Resolution: 16-bit
• Excitation Voltage Output : 0 ~ +10 V
• 50 Hz Event Counter (Digital Input)
• High/Low Alarm (Digital Output)
• 3000 VDC Intra-module Isolation
• Dual Watchdog
• Wide Operating Temperature Range: -25 to +75°C
Introduction
The “P” version of the I-7016 module is another milestone in the development of the I-7016 series, and is a testament to excellence by the R&D team at ICP DAS. The I-7016P is specifically designed for long-distance strain gauge measurement, and provides 1 Digital Input channel as a 50 Hz event counter and 4 Digital Output channels that can act as high or low alarms. The I-7016P also features 3000 VDC intra-module isolation.
Specification
CPU Module | |
---|---|
Watchdog Timer | Yes, Module (1.6 Seconds), Communication (Programmable) |
Isolation | |
---|---|
Intra-module Isolation | 3000 VDC |
EMS Protection | |
---|---|
EFT (IEC 61000-4-4) | 4 kV Contact for each Terminal 8 kV Air for Random Point |
ESD (IEC 61000-4-2) | ±4 kV for Power Line |
LED Indicators | |
---|---|
Status | 1 x Power and Communication |
Analog Input | |
---|---|
Channels | 1 |
Type | Strain Gauge |
Sensor Type | Full-Bridge |
Resolution | 16-bit |
Accuracy | ±0.05% of FSR |
Sampling Rate | 10 Hz |
Input Impedance | 20 MΩ |
Overvoltage Protection | ±5 VDC |
Long Distance Measurement | Yes |
Digital Input/Counter | |
---|---|
Channels | 1 |
Type | Dry Contact |
Sink/Source (NPN/PNP) | Source |
ON Voltage Level | Close to GND |
OFF Voltage Level | Open |
Max. Counts | 16-bit |
Frequency | 50 Hz |
Input Impedance | 3 kΩ |
Overvoltage Protection | ±30 VDC |
Digital Output | |
---|---|
Channels | 4 |
Type | Open Collector |
Sink/Source (NPN/PNP) | Sink |
Load Voltage | +3.5 ~ +50 VDC |
Max. Load Current | 30 mA/Channel |
Power on Value | Yes |
Safe Value | Yes |
Excitation Voltage Output | |
---|---|
Channels | 1 |
Range | 0 ~ +10 V |
Resolution | 16-bit |
Accuracy | ±0.05% |
Max. Load Current | 40 mA |
Power on Value | Yes |
COM Ports | |
---|---|
Ports | 1 x RS-485 |
Baud Rate | 1200 to 115200 bps |
Data Format | N, 8, 1 |
Protocol | DCON |
Power | |
---|---|
Reverse Polarity Protection | Yes |
Input Range | +10 ~ +30 VDC |
Consumption | 1.3 W |
Mechanical | |
---|---|
Dimensions (mm) | 123 x 72 x 35 (W x L x H) |
Installation | DIN-Rail |
Environmental | |
---|---|
Operating Temperature | -25 ~ +75 °C |
Storage Temperature | -40 ~ +85 °C |
Humidity | 10 ~ 95% RH, Non-condensing |
Download
Odering information
I-7016P CR | 1-ch 6-wire Strain Gauge Input Module using DCON Protocol (Blue Cover) (RoHS) |